Eversource East (formerly NSTAR) and National Grid agree with that height range from 3 ft to 6 ft, from finished grade/platform/finished floor to the center of the globe. Other utilities may have different acceptable ranges. Generally, the ideal position for the meter globe is at "eye level", which for a typical person is between 5 ft and 5'-6".

harley m8 header

Meter socket height nec

medical equipment china
the cider house rules analysis

balcones canyonlands indiangrass trail

News
explain the crime triangle

METER SOCKET ARRANGEMENT & REQUIREMENTS ... METER CLEARANCES AND METER HEIGHT ... In addition to PUD requirements, services must meet or exceed current NEC, NESC, Washington State Labor and Industries or other jurisdiction’s requirements and must be.

honor 7 inch phone

least thirty (30) inches in front of the meter. Meters shall be installed at a height of five (5) to seven (7) feet above the ground or ... self-contained 4-terminal meter socket. Posted September 6, 2007 Page 2 of 2 ... as specified in the NEC. Description. Eaton Ringless security meter breaker house panel has current rating of 400-Amps . This house panel has interrupt rating of 22-Kilo- Amps . It measures 29.75-Inch x 44-Inch. House panel is UL listed.

320a meter socket. side mount with trough combination 250a to 400a main panel. main panel 200a service conductors only main panel 250a or 400a 320a meter socket ground 2" nipples from panel to trough trough to be sized according to nec requirements 3" min. rigid nipple between meter socket and trough 3" min. rigid nipple between meter socket. Commercial ganged meter sockets shall be equipped with lever bypass. 6. The neutral connection shall be bonded to the meter socket enclosure. Also, an equipment ground stud provision, sized according to the National Electrical Code (NEC), is required in the load connection part of each meter socket for bonding purposes. 7. Meter Socket Jaws:. The height of the working space must be clear and extend from the grade, floor, or platform to a height of 6½ ft or the height of the equipment. Electrical equipment such raceways, cables, wireways, or panelboards or support structures (for example, concrete pads) can’t extend more than 6 in. beyond the front of the electrical equipment [Sec. 110.26(A)(3)] ( Fig. 3 ).

certified cultivators instagram

Service Mast, Surface-Mount Meter . Figure 2-5. Surface mounted meter installation. Figure 2-5 shows details of a service mast, with the meter on the surface of the building. The service could be wired to an exterior meter as shown here, or to service equipment inside the building. The customer installs everything in the pic- ture, except the. The NEC National Electrical Code does not specify a minimum height for a service meter, however the typical minimum height for mounting a service meter on side of a house is 5 to 6 feet above the finished grade or level ground. More about Electrical Services Home Electrical Codes for Services Basic House Wiring Circuits.

Tenant metering sections provide arrangements for grouping individual tenant feeder circuits rated 200 A or less. Each circuit consists of a utility approved meter socket and OCPD. These sections contain factory-assembled and wired meter sockets and disconnects arranged for hot sequence metering (meter socket ahead of the tenant disconnect).